Pharmatainer™ bottles are available in sizes ranging from 125 mL to 2 liters, made in PC. They are injection blow molded and capped in an ISO 5 cleanroom environment and then packaged in an ISO 7 cleanroom with inner layer vacuum sealed packaging. As per the manufacturer, they are designed for biomanufacturing liquid transfer, storage and transport. and the PC bottles, when used with a PP cap, can be autoclaved at a recommended 121C. Pharmatainer™ caps (part numbers 12716–12719) are available and feature barbed port configurations for use with these bottles.
Technical Detail 2 Liter; 48 mm cap
Materials PC HDPE
CAD Model Available No
Manufacturing Environment Classification ISO Class 7 / 10,000 / Grade C
Manufacturing Aids - Mold Release - Lubricant used No
Colorant in Part No
Regrind Used to Manufacture This Part No
Hazardous Goods No
Product Shelf Life Non-Irradiation (months) 84
Animal Derived Ingredients (BSE/TSE) Animal Derived Component Free (ADCF)
California Prop. 65 Information Not Available
Conflict Minerals Not known to contain tantalum, tin, tungsten or gold.
European Pharmacopoeia (EP) 3.1.X Information Not Available
Human Derived Ingredients Does NOT intentionally contain human derived ingredients
Latex Does NOT intentionally contain natural latex
Latex in Packaging Does NOT intentionally contain natural latex
Medicinal Substances Does NOT intentionally contain medicinal substances
Nanomaterials Does NOT intentionally contain nanomaterials
Pyrogens Not tested for pyrogens
REACH SVHC No Substance(s) Present Above Threshold
RoHS3 (2015/863) Conforms to requirements of RoHS 2015/863 (RoHS3)
Gamma Compatible Yes
X-Ray Compatible Yes
Biocompatibility tested ISO 10993 Yes
ISO 10993-X Claim Based on Raw Material
USP Biocompatibility 87 Finished component passes USP<87>
USP Biocompatibility 88 Passes USP <88>, temperature not stated
USP Biocompatibility Claim Based On Finished Component
Residual Solvents: Tested via ICH Q3C Standard No ICH Q3C Testing Performed
Elemental Impurities: Tested via ICH Q3D Standard Contains NO ICH Q3D Class 1, 2, 2B or 3 Elemental Impurities
Protein Absorption Data Available No
Extractables Testing Claims Suitable for intended use according to USP <665>
Visible-Subvisible Particulate Claim USP <788>
Bioburden USP 61 62 Bioburden values available
Tested via USP 661.1 No
Integrity Tested? Yes, 100%

The products in our inventory are intended solely for use as components for further manufacturing, processing or incorporation into a finished device. These products are not intended for use as finished devices. Customers are solely responsible for determining whether a Qosina component product is appropriate for customer’s intended use and for ensuring that the use of the component product is in compliance with applicable laws. Our components are not available for sale to hospitals, physicians, and pharmacists.