PharmaTainer™ Carboy, Non-Sterile, 1/Vacuum Sealed Pack
Technical Features
Materials
Please log in or register to view pricing, download product documentation and CAD models.
| Technical Detail | 10 Liter; 70 mm cap |
| Materials | COPE HDPE |
| CAD Model Available | No |
| Manufacturing Environment Classification | ISO Class 5 / 100 / Grade A |
| Manufacturing Aids - Mold Release - Lubricant used | No |
| Colorant in Part | No |
| Regrind Used to Manufacture This Part | No |
| Hazardous Goods | No |
| Product Shelf Life Non-Irradiation (months) | 84 |
| Animal Derived Ingredients (BSE/TSE) | Animal Derived Component Free (ADCF) |
| Conflict Minerals | Not known to contain tantalum, tin, tungsten or gold. |
| Human Derived Ingredients | Does NOT intentionally contain human derived ingredients |
| Latex | Does NOT intentionally contain natural latex |
| Latex in Packaging | Does NOT intentionally contain natural latex |
| Medicinal Substances | Does NOT intentionally contain medicinal substances |
| Nanomaterials | Does NOT intentionally contain nanomaterials |
| Pyrogens | Not tested for pyrogens |
| REACH SVHC | No Substance(s) Present Above Threshold |
| REACH SVHC Candidate List | 2025 January 21 (247 Substances) |
| RoHS3 (2015/863) | Conforms to requirements of RoHS 2015/863 (RoHS3) |
| Gamma Compatible | Yes |
| X-Ray Compatible | Yes |
| Biocompatibility tested ISO 10993 | Yes |
| ISO 10993-X Claim Based on | Raw Material |
| USP Biocompatibility 87 | Finished component passes USP<87> |
| USP Biocompatibility 88 | Passes USP <88>, temperature not stated |
| USP Biocompatibility Claim Based On | Finished Component |
| Residual Solvents: Tested via ICH Q3C Standard | Contains NO ICH Q3C Class 1 or 2 Residual Solvents |
| Elemental Impurities: Tested via ICH Q3D Standard | Contains NO ICH Q3D Class 1, 2, 2B or 3 Elemental Impurities |
| Protein Absorption Data Available | No |
| Extractables Testing Claims | Suitable for intended use according to USP <665> |
| Visible-Subvisible Particulate Claim | USP <788> |
| Bioburden USP 61 62 | Bioburden values available |
| Integrity Tested? | Yes, 100% |
The products in our inventory are intended solely for use as components for further manufacturing, processing or incorporation into a finished device. These products are not intended for use as finished devices. Customers are solely responsible for determining whether a Qosina component product is appropriate for customer’s intended use and for ensuring that the use of the component product is in compliance with applicable laws. Our components are not available for sale to hospitals, physicians, and pharmacists.