RCP004

Hemostasis Y Connector with Swabbable Side Port

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting the male luer on the swabbable valve (80326) to the female side port of the hemostasis valve (80147), you can add a leak-resistant seal on the sideport access for flushing and lubrication. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP012

Barbed Filter

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a male luer lock to barb connector (11553) on the inlet of a hydrophobic filter (28213), and a female luer lock to barb (11554) to the filter outlet, you can create a barbed hydrophobic filter assembly. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP016

Closed Male Luer Lock Extension Line

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a closed male luer lock valve connector (90402) to a PVC tube (T4306) and a male luer with spin lock to barbed connector, you can create an extension line that can aspirate or drain fluid. Include a pinch clamp (13600) to control the flow of fluids. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP017

Flow Control Line

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By combining a flow controller (21292) with a PVC tube (T4306), male and female luer lock connectors (65260 and 712991) and injection site (80005), you can create an extension line that boasts flow control and line access . Include a cap (65511) to complete this sub-assembly. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP028

Injection Site with Dual Sideport Valves

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting PVC tubing (T4300) to the tubing ports on a double T injection site connector (80016), you can then connect female luer locks (65202) to the tubes with swabbable valves (80213), that will create a unique combination for injection and sampling. Include slide clamps (12064) to control the flow. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP029

Dual Check Valve with Tube

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a PVC tube (T4306) to a dual check valve (QOS5401086SN), you can add a male luer lock connector (89342) to the tube to easily transfer fluids from one receptacle to another. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP007

Parallel Y Connector with Female Luer Locks and Bayonnet Fitting

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting female luer locks (11530) and a bayonnet fitting (64113) to our plastisol Y connector (81250), you can create a blood pressure cuff adapter. Utilize a cable tie (99989) to secure the connection. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP020

Luer Activated Tri-Y Connector

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting the male luer lock on luer activated valves (80363) to the female luer locks of a Y connector (65925), you can offer bidirectional access to a line. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP022

Tri-Port Luer Extension Line with Swabbable Valves

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a 3-way parallel tubing connector (64101) to PVC tubes (T4300), you can connect three swabbable luer-activated valves (80163) along with slide clamps (12064), which will provide you three female luer lock inlets to one male luer lock outlet. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP023

Extension Line, Female Luer Locks to Male Luer Lock

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By utilizing a parallel Y connector (83057), you can create a tubing line that joins two lines into one. Simply connect a PVC tube (T4305) and multiple luer lock connectors with caps (65106, 65245, 80385 and 65501) to your parallel connector to create this extension line. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP033

ENPlus Spike to ENFit™ Connector Extension Line

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a female ENFit™ connector (40071) to a PVC tube (T4306) and ENPlus spike (40009), you can create an extension line that helps prevent small-bore misconnections. Include a pinch clamp (13606) to control the flow of fluids. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP034

ENFit™ Connector with Tube

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. You can connect a PVC tube (T4304 ) to a male ENFit™ connector to create a transfer tube, which can withdraw fluids from deep packaging. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP035

Valve with Sideport Luer and Cap

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. Connect an endoscopic valve (80368) to the female luer lock on a Y connector (83016) to allow passage of 0-5 Fr instruments without leakage. Add a non-vented cap (65413) to the second arm of the Y connector as a dust cover while not in use for flushing or sampling. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP037

Dual Tuohy Borst Y Connector with Swabbable Sideport

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting multiple tuohy borst adapters to a Y connector (83010), you can create sealed ports on all access points. Connect a FLO 30™ tuohy borst adapter (80330) to the bottom port of the Y connector while connecting a self-sealing hemostasis valve (33058) to the top port to create this sub-assembly. Add a swabbable injection site (80147) to the female luer lock side port to aid in irrigation. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP038

Stopcock with One-Way Swabbable Sampling Valve

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a swabbable, needless one-way sampling valve (90403) to a 3-way stopcock, you can create a unique assembly for flow-controlled sampling. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP015

Transfer Line

With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a dual check valve (QOS5401086SN) and a vented spike (23205) to a PVC tube (T4306), you can easily create an extension line for fluid transfer. Include a pinch clamp (14042) to control the flow of fluids when transferring from one receptacle to another. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED
RCP116

Stopcock Extension Line with Swabbable Valve

With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a male luer lock to barbed connector (89342)and 3-way stopcock (99165) to a PVC tube (T4306) you can create a stopcock extension line. Add a swabbable needleless injection site (80212) to complete the valved assembly. Additional material and size options may be available. Contact our sales team to learn more.
ⓘ ASSEMBLY REQUIRED