BIY Assemblies

If you would like to see pricing for our BIY Assemblies or request free samples, please log in or register.

BIY Assemblies

per page
  • RCP051

    Oxygen Bushing Adapter

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a female luer lock (11150) to an oxygen bushing (13105) you can create a flexible respiratory adapter for luer locks.Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP052

    Stepped Adapter with Luer Lock Connector

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By inserting the tubing port from a male luer lock connector (71627) into the ID of the male luer slip port of a stepped connector (41410), you can connect a female luer lock connector for withdrawal or delivery. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP053

    Insufflation Tubing Adapter

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a respiratory straight connector (51449) to a PVC tube (T4311) and female luer lock to babred connector (11550), you can create an insufflation tubing line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP055

    Fluid line with Spike, Clamp and Injection Port

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting PVC tubing (T4305) to a vented spike/chamber assembly (X2011), male luer lock connector (65113) and Y injection site (12102), you can create a flush extension line. Include a roller clamp (X80021 & X80022), a luer cap (65700) and cohesive tape (17623) to complete the assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP056

    Spike line with Clamp

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting PVC tubing (T4312) to a vented spike (23209) and female luer lock connector, you can easily create an extension line for drainage. Add a pinch clamp (14105) and cap to the female luer lock (65289) to complete the assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP057

    Extension Line with Swabbable Valve, Slide Clamp and Male Luer Loc...

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting PVC tubing (T4303) to a swabbable needleless injection site (80163) and male luer lock connector (71635), you can easily create a swabbable site extension line. Include a slide clamp (11056) to complete the assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP059

    Quick Disconnect Extension Line with Clamp and Plug

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a PVC tube (T2205) with a pinch clamp (11498) to a quick disconnect coupling (MPX1703) and plug (MPX3003M), you can create an extension line that can be attached to a bioprocess bag for small volume applications. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP062

    ENFit® Bottle Neck Adapter

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a tapered bottle adapter (89208) to a male ENFit® connector (40077), you can create an ENFit® sampling cap. Add a female ENFit® cap (40079) and strap (40095) to complete the assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP063

    Breathing Bag with Reducing Connector

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a straight adapter (51287) to a breathing bag (54935) and a pediatric adapter (51283) you can reduce the size of the access port on the breathing bag for smaller oxygen tubes. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP064

    3-Way Stopcock Line with Adapter and Pinch Clamp

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting PVC tubing (T4008) to a 3-way stopcock (13127) and stepped adapter (11480), you can create an extension line that offers 3-way control of fluids. Complete the line by adding a pinch clamp (13997). Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP065

    Stepped Adapter with Luer Lock Connectors

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a stepped adapter (41414) to a PVC tube (T4305) and female luer lock connector (11149), you can allow for a male luer lock to be connected to the stepped adapter. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP066

    Bag with Spike Port

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting an injection port with sterilization ring (49005) and cap to a PVC bag (28513), you can create a bag with port assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP116

    Stopcock Extension Line with Swabbable Valve

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a male luer lock to barbed connector (89342)and 3-way stopcock (99165) to a PVC tube (T4306) you can create a stopcock extension line. Add a swabbable needleless injection site (80212) to complete the valved assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED