BIY Assemblies

If you would like to see pricing for our BIY Assemblies or request free samples, please log in or register.

BIY Assemblies

per page
  • RCP027

    Universal Connector Extension Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting suction connectors (57025) to a PVC tube (T4313), you can create an extension line for suction or oxygen. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP028

    Injection Site with Dual Sideport Valves

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting PVC tubing (T4300) to the tubing ports on a double T injection site connector (80016), you can then connect female luer locks (65202) to the tubes with swabbable valves (80213), that will create a unique combination for injection and sampling. Include slide clamps (12064) to control the flow. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP029

    Dual Check Valve with Tube

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a PVC tube (T4306) to a dual check valve (QOS5401086SN), you can add a male luer lock connector (89342) to the tube to easily transfer fluids from one receptacle to another. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP030

    Spike Transfer Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a PVC tube (T4311) to a non-vented spike (22224) and stepped connector (21177), you can create a high-flow fluid transfer extension line. Include a pinch clamp (14083) to control the flow of fluids within the line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP031

    Spike Transfer Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a PVC tube (T4313) to the barbed ends of two non-vented spikes, you can create a high-flow fluid transfer extension line. Include a pinch clamp (13997) to control the flow of fluids within the line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP032

    Spike with Tube

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a PVC tube (T4313) to a barbed non-vented spike (31297), you can quickly decanter from a bag or bottle. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP033

    ENPlus Spike to ENFit® Connector Extension Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a female ENFit® connector (40071) to a PVC tube (T4306) and ENPlus spike (40009), you can create an extension line that helps prevent small-bore misconnections. Include a pinch clamp (13606) to control the flow of fluids. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP034

    ENFit® Connector with Tube

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. You can connect a PVC tube (T4304 ) to a male ENFit® connector to create a transfer tube, which can withdraw fluids from deep packaging. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP035

    Valve with Sideport Luer and Cap

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. Connect an endoscopic valve (80368) to the female luer lock on a Y connector (83016) to allow passage of 0-5 Fr instruments without leakage. Add a non-vented cap (65413) to the second arm of the Y connector as a dust cover while not in use for flushing or sampling. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP036

    Tuohy Borst Y Connector with Female Luer Lock Sideport

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a FLO 30™ tuohy borst adapter (80330) to the female luer lock of a Y connector (83016), you can allow for the passage of 0-9 Fr instruments without leakage. Add a non-vented cap (65413) to the second arm of the Y connector as a dust cover while not in use for flushing or sampling. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP037

    Dual Tuohy Borst Y Connector with Swabbable Sideport

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting multiple tuohy borst adapters to a Y connector (83010), you can create sealed ports on all access points. Connect a FLO 30™ tuohy borst adapter (80330) to the bottom port of the Y connector while connecting a self-sealing hemostasis valve (33058) to the top port to create this sub-assembly. Add a swabbable injection site (80147) to the female luer lock side port to aid in irrigation. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP038

    Stopcock with One-Way Swabbable Sampling Valve

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a swabbable, needless one-way sampling valve (90403) to a 3-way stopcock, you can create a unique assembly for flow-controlled sampling. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP039

    Female Luer Lock to Male Large Bore Adapter

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a large-bore, high-flow male connector (98653) to the oral slip connector of a female luer lock to oral slip connector (23273), you can create a tube set to bag adapter. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP040

    Large Bore Female Connector to Tube

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a PVC tube (T4311) to a large-bore female connector (99921), you can create an extension line that allows you to extract or dispense fluids. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP041

    Stepped Adapter with Cap on Strap

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a cap on a strap (65453) to a stepped female luer lock connector (11519), you can seal off the access port when multiple access is needed. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP042

    4-Way Stopcock with Syringes

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting the female luer locks on a 4-way stopcock (99781) to two syringes (C1084), you can mix substances before delivery. Utilize a non-vented female cap (65700) to close the open male luer lock port on the stopcock. Additional material and size options may be available. Contact our sales team to lean more.
    ⓘ ASSEMBLY REQUIRED
  • RCP015

    Transfer Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a dual check valve (QOS5401086SN) and a vented spike (23205) to a PVC tube (T4306), you can easily create an extension line for fluid transfer. Include a pinch clamp (14042) to control the flow of fluids when transferring from one receptacle to another. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP043

    Female Luer Lock to Female Large Bore Adapter

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a large-bore, high-flow female connector (98613) to the oral slip connector of a female luer lock to oral slip connector (23273), you can create a tube set to bag adapter. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP044

    Stepped Adapter with Luer Lock Connectors

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a female luer lock connector (65266) to the male luer slip port of a stepped connector (41410), you can connect a male luer lock connector for withdrawal or delivery. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP049

    Insufflation Filter Extension Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting PVC tubing (T4313) to a barbed insufflation filter (11679) and male luer lock connector (90245), you can create an extension line that filters gas. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP045

    Dual Check Valve T Connector

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting the male luer lock outlets from two duckbill check valves (80065) to either side of a female luer lock t connector (88214) you can create an adapter that provides the ability to control backflow in two directions.Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP047

    Dual Check Valve with Syringe

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting the female luer lock on a dual check valve (80187) to a control syringe (C1065), you can have a control port for fluid withdrawl and delivery.Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP048

    Extension Line with Swabbale and Pressure Activated Check Valve

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a Y connector (65900) to a needless swabbale valve (80189) and check valve (80188) you can create an extension line that offers site access and flow control. Add a pinch clamp (14036), male luer lock connector (712991) and cap (65701) to complete the line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP050

    Swabbable Access Site with Tube Connector line and Clamp

    With thousands of stock components, it is easy to build your own sub-assembles from our line of products. By connecting a swabbable needleless valve and cap (80147 and 12084) to a female luer lock (11149), you can connect a PVC tube (T4305) with clamp (14042) and tubing connector (41414) to create an extension line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED