BIY Assemblies

If you would like to see pricing for our BIY Assemblies or request free samples, please log in or register.

BIY Assemblies

per page
  • RCP001

    Swabbable Vial Adapter; 17 mm - 20 mm

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. Simply connect the male luer lock on the swabbable valve (80147) to the female luer lock port on the vial adapter (25663) to create a closed, swabbable vial access transfer assembly for 17 mm – 20 mm vials. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP002

    Swabbable Vial Adapter; 13 mm

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. Simply connect the male luer lock on the swabbable valve (80147) to the female luer lock port on the vial adapter (25662) to create a closed, swabbable vial access transfer assembly for 13 mm vials. Additional material and size options may be available. Contact our sales team department to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP003

    Swabbable Vial Adapter; 17 mm - 20 mm

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. Simply connect the male luer lock on the swabbable valve (80147) to the female luer lock port on the vial adapter (25662) to create a closed, swabbable vial access transfer assembly for 13 mm vials. Additional material and size options may be available. Contact our sales team department to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP004

    Hemostasis Y Connector with Swabbable Side Port

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting the male luer on the swabbable valve (80326) to the female side port of the hemostasis valve (80147), you can add a leak-resistant seal on the sideport access for flushing and lubrication. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP005

    Universal Stepped Connector with Female Luer Lock

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a barb to female luer lock connector (11550) to a universal flexible connector (580121), you can connect a male luer lock to a suction connector instead of bonding it to a tube. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP006

    Universal Stepped Connector with Male Luer Lock

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a barb to female luer lock connector (11531) to a flexible connector (580302), you can connect a male luer lock to a suction connector instead of bonding it to a tube. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP007

    Parallel Y Connector with Female Luer Locks and Bayonnet Fitting

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting female luer locks (11530) and a bayonnet fitting (64113) to our plastisol Y connector (81250), you can create a blood pressure cuff adapter. Utilize a cable tie (99989) to secure the connection. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP008

    Tube with Straight Connector

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a barbed straight connector (25653) to a PVC tube (T4313), you can create a drainage, flushing or fluid transfer assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP009

    Swabbable Transfer Spike

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a needleless injection site (91042) to a mini transfer spike (23258), you can create a swabbable transfer spike assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP010

    Extension Line with Stopcock

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a 3-way stopcock (99520) to a standard male to female extension line (33061), you can enhance the line by adding flow control and additional ports for fluid connection. Incorporate caps (11639) to complete the extension. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP012

    Barbed Filter

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a male luer lock to barb connector (11553) on the inlet of a hydrophobic filter (28213), and a female luer lock to barb (11554) to the filter outlet, you can create a barbed hydrophobic filter assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP013

    Barbed Stopcock

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a female luer lock to barb connector (11394) to the swivel male luer lock of a 3-way stopcock (99730) and a male luer lock to barb connector to each of the female luer lock ports, you can easily add tubing to a stopcock. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP014

    Extension Line with Stopcock

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a 1-way stopcock (99759) to a female to male luer lock extension line (36213), you can add flow control to your fluid connection. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP016

    Closed Male Luer Lock Extension Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a closed male luer lock valve connector (90402) to a PVC tube (T4306) and a male luer with spin lock to barbed connector, you can create an extension line that can aspirate or drain fluid. Include a pinch clamp (13600) to control the flow of fluids. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP017

    Flow Control Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By combining a flow controller (21292) with a PVC tube (T4306), male and female luer lock connectors (65260 and 712991) and injection site (80005), you can create an extension line that boasts flow control and line access . Include a cap (65511) to complete this sub-assembly. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP018

    Hemostasis Valve Y Connector with Stopcock Sideport

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By bonding a PVC tube (T4306) into the female luer lock sidearm of a hemostasis valve (80328), you can add a 4-way stopcock (99680) to the other end of the tube, creating a 4-way stopcock sideport. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP019

    T Connector Extension Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting an injection site (84039) and T connector (80061) to an already-existing extension line (17648), you can create an extension line that provides the ability to inject and sample using a needle. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP020

    Luer Activated Tri-Y Connector

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting the male luer lock on luer activated valves (80363) to the female luer locks of a Y connector (65925), you can offer bidirectional access to a line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP021

    Breathing Bag with Connector

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. Easily reduce the size of a breathing bag's (54938) oxygen bushing by utilizing reducer connectors (5099 and 51054). Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP022

    Tri-Port Luer Extension Line with Swabbable Valves

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a 3-way parallel tubing connector (64101) to PVC tubes (T4300), you can connect three swabbable luer-activated valves (80163) along with slide clamps (12064), which will provide you three female luer lock inlets to one male luer lock outlet. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP023

    Extension Line, Female Luer Locks to Male Luer Lock

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By utilizing a parallel Y connector (83057), you can create a tubing line that joins two lines into one. Simply connect a PVC tube (T4305) and multiple luer lock connectors with caps (65106, 65245, 80385 and 65501) to your parallel connector to create this extension line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP024

    Dual Stopcock with Swabbable Valves

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting the male luer slip on a 4-way stopcock (99773) to the female luer lock port of the same 4-way stopcock (99773), you can create a manifold that features two swabbable valves with the ability to control the flow. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP025

    Stepped Adapter Extension Line with Universal Connector and Pinch ...

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a stepped connector (41410) to a PVC tube (T4305) and universal connector (580121), you can create an extension line to be utilized for drainage. Include a pinch clamp (13604) to offer flow control within the line. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED
  • RCP026

    Sanitary Flange Extension Line

    With thousands of stock components, it is easy to build your own sub-assemblies from our line of products. By connecting a sanitary flange (51606) to C-Flex tubing (T2205) using a non-reopening cable tie (99990), you can create a quick extension line for your bioprocessing project. Additional material and size options may be available. Contact our sales team to learn more.
    ⓘ ASSEMBLY REQUIRED